C-flex® and Superflex® Aspheric Monofocal

C-flex® and Superflex® Aspheric Monofocal

Built on the proven Rayner Primary IOL Platform, the C-flex Aspheric and Superflex Aspheric are hydrophilic acrylic aspheric monofocal IOLs with a 360° enhanced square edge and true aberration-neutral optic technology.

We believe that every patient’s vision is important and there is no such thing as the “average” cornea. That’s why the Rayner C-flex Aspheric and Superflex Aspheric lenses are aberration neutral, allowing patients to benefit from the natural residual positive aberration of the cornea.

C-flex Aspheric is the 5.75 mm diameter monofocal optic, manufactured in powers from +8.0 to +34.0 D.

Superflex Aspheric is a 6.25 mm diameter monofocal optic, manufactured in powers from -10.0 to +22.0 D.

 

Patients deserve optimal visual quality and functional visual acuity in all light conditions

Aspheric IOL with aberration-neutral technology:

 
  • Offer improved contrast sensitivity compared with spherical IOLs3,4
  • Provide better low light level visual acuity than spherical IOLs18
  • Can offer more depth of field than aberration-negative IOLs by retention of the patient’s natural level of corneal spherical aberration6
  • Are less susceptible to the effects of decentration than aberration-negative IOLs12

Spherical IOL:

 
Spherical IOL
Power increases from centre to edge.

Disadvantages

  • Adds to corneal positive spherical aberration (SA)
  • Degrades image quality and contrast sensitivity

Aberration-neutral aspheric IOL

 
Aberration-neutral aspheric IOL
Prolate anterior surface means uniform power from centre to edge. Aberration-neutral optic retains natural residual positive SA of the cornea.

Advantages

  • High quality vision in all lighting conditions
  • Good contrast sensitivity
  • More depth of field than an aberration-negative aspheric IOL
  • Optimal results for ALL patients; not just for the “average” cornea

Why is it important to retain depth of field?

Patients prefer a lens that retains depth of field6

 
Simulation of retained depth of field
Simulation of retained depth of field
Simulation of reduced depth of field
Simulation of reduced depth of field
  • Retention of some positive SA can provide up to 0.5 D of pseudo-accommodation, offering preferable visual outcomes
  • - In a clinical trial of 80 patients where an aberration-neutral lens was implanted in one eye and an aberration-negative lens was implanted in the other eye:6
2 x as many
patients* preferred the aberration-neutral IOL
* Of those patients who expressed a preference
3 x fewer
reports of visual disturbances with the aberration-neutral IOL
Both C-flex Aspheric and Superflex Aspheric IOLs are supplied with a Rayner injector
  • Uniquely designed loading bay with an extension "lip" to facilitate loading.
  • Soft plunger tip completely fills the nozzle and offers a soft protective interface with the IOL.
  • Syringe-style design for single-handed technique for smooth IOL delivery with predictable and efficient insertion, ensuring consistent IOL implantations.
  • Sterile Single-Use, ready to use.
Model Name: C-flex Aspheric
Model Number: 970C
Power Range:

+8.0 D to +29,5 D (0.5 D increments)
+30.0 D to +34.0 D (1.0 D increments)

Optic Diameter: 5.75 mm
Overall Length: 12.00 mm
Model Name: Superflex Aspheric
Model Number: 920H
Power Range:

-10.0 D to -1.0 D (0.5 D increments)
+1.0 D to +22.0 D (0.5 D increments)

Optic Diameter: 6.25 mm
Overall Length: 12.50 mm
Delivery System
Injector Type: Sterile Single use loadable injector
Nozzle Size: 2.00 mm
Bevel Angle: 45°
Lens Delivery: Single handed plunger
Aspheric Monofocal IOL
Material: Single piece Rayacryl® hydrophilic acrylic
Water Content: 26% in equilibrium
UV Protection: Benzophenone UV absorbing agent
UV light transmission: UV 10% cut-off is 380 nm
Refractive Index: 1.46
Optic Shape: Biconvex (positive powers), Biconcave (negative powers)
Asphericity: Anterior aspheric surface with aberration-neutral technology
Optic Edge Design: Amon-Apple 360° enhanced square edge
Haptic Angulation: 0°, uniplaner
Haptic style: Closed loop with anti-vaulting haptic (AVH) technology
Estimated constants for optical biometry SRK/T: 118.6
Estimated constants for Ultrasound A-constant: 118.0

*Please note that the constants indicated for all Rayner lenses are estimates and are for guidance purposes only. Surgeons must always expect to personalise their own constants based on initial patient outcomes, with further personalisation as the number of eyes increases.

Not all products or offerings are approved or offered in every market and approved labelling and instructions may vary from one country to another. For country specific product information contact your local distributor or email iol_enquires@rayner.com.

Superflex is not approved by the FDA for use or distribution in the United States of America. For FDA status on C-flex please contact the Regulatory Affairs team

Rayner hold a selection of EC certificates for various products. Please contact the Regulatory Affairs team for the current version.

Scientific Papers and Supporting Materials